Conversion of an existing system in Germany and delivery:

Water control valve

Type AMV-50-50-PN100

Pipe connection

Inlet DN50 PN100 Flange version

Material P250GH

Outlet DN50 PN100 Flange version

Material P250GH

Calculation pressure PS= 63 bar

Calculation temperature TS= 250°C

Seat: Ø32 / 25mm

Stroke: 25mm

Number of stages: 3

Characteristic curve: Equal percentage

Equipment:

Valve equipped with two-stage control body as radial stage nozzle and

additional outlet cone to protect against cavitation damage.

There is an additional bushing in the outlet to prevent cavitation damage in the outlet.

prevents cavitation damage in the outlet. Stuffing box seal design according to VGB guideline.

Actuator:

On-site synchronized cylinder provided by customer free of charge

Type: GZ 50/28*28*40

Limit switch:

Make: Schmersal

Type: ZK4 235-11Z

1 * “Open” position

1 * “Closed” position

More news

Preheating protection for Finland

Preheater Protection Inlet Valve 3-Way Valve Type APPIV-300-300-300-PN250 Dimensions of pipe connection: Inlet / outlet: 323,9 x 16 mm and bypass Bypass: 273,0 x 16…

Injection cooler

Type AEK-300-80-PN100 existing pipe connection dimension steam pipe: Inlet Ø 323.9 * 7.1 mm Outlet Ø 323.9 * 7.1 mm Water pipe connection Flange DN50…