Steam conditioning station with downstream motive steam injection

Water injection via spring-loaded injection nozzle in the outlet, corner body design

Nominal size / pressure rating:
Inlet DN400 / PN64
Outlet DN800 / PN16
Material 16Mo3

Water injection DN40 PN160
Material 16Mo3
Flange design EN1092-1/B1

Design parameters:
Calculation pressure
Inlet: 56 bar
Outlet: 14 bar
Calculation temperature
Inlet: 450 °C
Outlet: 200 °C

More news

Preheating protection for Finland

Preheater Protection Inlet Valve 3-Way Valve Type APPIV-300-300-300-PN250 Dimensions of pipe connection: Inlet / outlet: 323,9 x 16 mm and bypass Bypass: 273,0 x 16…

Injection cooler

Type AEK-300-80-PN100 existing pipe connection dimension steam pipe: Inlet Ø 323.9 * 7.1 mm Outlet Ø 323.9 * 7.1 mm Water pipe connection Flange DN50…