Steam Converting Valve

Valve body design straight through
With integrated water injection valve

Inlet DN200
Flange DN200/PN40
Material: GP240GH (1.0619)
Outlet DN200
Flange DN200/PN40
Material: GP240GH (1.0619)
Water Connection DN25 PN40
Flange
Material: C 22.8 (1.0460)

Designparameter
Inlet PS= 22 bar, TS=250°C
Outlet PS= 22 bar, TS= 250°C
Pneumatical actuator, Fabricate AAS
Type: 2116-1200-100-HO-FS
Air opens, spring closes (reverse acting)
incl. Manometer. (0-6 bar)
Positioner Standard
feedback 4-20mA incl.
pressure gauge. (0-6 bar)
Control Input 4…20mA
Two-wire technology Limit switch (Microswitch)
Air filter regulator
Air supply
Required air supply: 5,0 bar
Piping: VA 8×1
Air supply
Required air supply: 5,0 bar

More news

Preheating protection for Finland

Preheater Protection Inlet Valve 3-Way Valve Type APPIV-300-300-300-PN250 Dimensions of pipe connection: Inlet / outlet: 323,9 x 16 mm and bypass Bypass: 273,0 x 16…

Injection cooler

Type AEK-300-80-PN100 existing pipe connection dimension steam pipe: Inlet Ø 323.9 * 7.1 mm Outlet Ø 323.9 * 7.1 mm Water pipe connection Flange DN50…